Canon IU-16/IU-40 Interpolator Board
From Partnumber.org Part Numbers, SKUs, Product Information Directory
|
Contents |
[edit] Product Name
Canon IU-16/IU-40 Interpolator Board
[edit] Manufacturer Part Number
IU-16/IU-40
[edit] Product Date
circa January 2008
[edit] Product Image
[edit] Manufacturer Provided Specifications and Description
- Overview
Electric interpolator unit includes power supply.
- Features
- Maximum frequencies of input signals are IU-40 : 300kHz, IU-16 : 500kHz.
- A phase B phase square wave signal output (PCA,PCB) and UP/DOWN pulse output function are equipped.
- Differential line Driver output.
- Specifications
| Input signals | Canon encoder A phase, B phase sine wave signal |
standard voltage 1 Vp-p (no load, output impedance 110 ohm) |
| Canon encoder Z phase signals | Open corrector or Balanced Line Driver | |
| Output signals | up / down pulse signal | Pulse width : 70 ± 20 nsec ( can be changed to 30 ± 10 nsec ) |
| A, B phase signal | Divided rectangle signal (PCA+, PCB+, PCA-, PCB-), Differential Line Driver | |
| Z phase signal | Pulse width (PCZ+, PCZ-) : 330 ± 80 µm (can be changed) | |
| Output type |
Differential line drivers | |
| Input signals response frequency |
500 kHz max. | |
| Division accuracy |
One cycle of the encoder output is "a", the interval of adjoining pulse is a / 16 (1 ± 1 / 4) | |
| Power supply | voltage |
AC 90 ~ 132 V, 50 ~ 60 Hz |
| power consumption |
18 W max. | |
| Dimensions |
180 x 285 x 70 mm | |
| Ambient conditions | Operating Temperature |
0 to 50 ºC |
| Storage Temperature | -20 to 70 ºC | |