Canon TX-F Full Auto Tonometer


[edit] Manufacturer Part Number

TX-F


[edit] Product Date

circa November 2006


[edit] Product Image

Image:Canon_TX-F.jpg


[edit] Manufacturer Provided Specifications and Description

  • Overview

The Canon TX-F Full Auto Tonometer is very easy to operate using the auto-feature. Once the eye is located on the alignment screen, just press start! The motorized optical head automatically aligns, acquires the readings, and then automatically moves over to the opposite eye to perform the same function. The unit can also be operated manually to acquire readings.


  • Features

Selectable Measurement Modes

The three-dimensional tracking system of the TX-F features a wide range of movement, so that the examinee’s pupil can be detected right away. The trackball and roller combination allow you to perform manual alignment with your fingertips alone. For added flexibility, the TX-F includes auto and manual measurement modes.


IOP Warning Display

The TX-F helps you diagnose ocular hypertension without delay by displaying a warning message whenever high pressure is detected. You can enter any threshold value on the unit’s settings screen, and this will activate the TX-F’s warning system for that value. When running the TX-F in Full Auto mode, operation will be halted when the threshold is exceeded.


Visual Confirmation of Errors

When a reading cannot be made, the TX-F will show you a snapshot of the examinee’s eye, giving you the information you need to make a correction. At a glance, you’ll know whether it was an eyelid, eyelash, or the eye being out of position that caused the error. A short message will tell you what action to take, such as adjusting the chin rest or limiter.


Soft Air Puff

For most patients, the only thing remarkable--and worrisome--about tonometry is the air puff. The TX-F employs one of the most delicate air puffs of any non-contact tonometer for patient comfort.


Centralized Controls

Alongside the trackball and roller, the TX-F features a control panel that puts keys for all major functions in one area. So whether you’re switching the measurement mode or just want to adjust the chin rest, you can get anything done with maximum ease.


Display by Order or Reliability

Internal memory provides storage of up to 10 measurements for each eye listing in the order they were taken or by reliability. A printout or data transfer can be automatic.


  • Specifications

General

Type

Non-contact

Measurable range

0-60 mmHg (Includes automatic shifting between 30/60 mmHg)

Measuring increment

1 mmHg

Operation distance

Approximately 11 mm from front of nozzle

Alignment

Full Auto/ Auto/ Manual

Observation range

Approximately 15 mm x 12 mm

Memory

Maximum of 10 measurements for each eye

Printer

Thermal line printer

 

 

Electrical and Environmental

Power supply

AC 100-240V, 50/60Hz, 0.4-0.8A

 

 

Physical Characteristics

Dimensions (W x L x H)

11.0 inches x 20.5 inches x 19.5 inches
(280 mm x 520 mm x 495 mm)

Weight

Approximately 20.5 kg (45.2 pounds)